The explosion proof cable glands are normally installed in the chemical and petrochemical plants, off-shore platforms, refineries and any other industry where hazardous atmospheres (gas and combustible dust) are present.
The cable gland series are designed to allow direct entry of armoured cables into Ex d and Ex e enclosures to provide any electrical connection with external circuits.
Code | Ø | D1 | D2 | H | L | CH | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Metric | NPT | min | max | min | max | min | min | 1 | 2 | 3 | ||
![]() |
CGA01*^ | M16 X 1.5 | 3/8" | 6 | 12 | 3 | 8.5 | 47 | 16 | 22 | 26 | 26 |
CGA011*^ | M16 X 1.5 | 3/8" | 8.5 | 16 | 6 | 12 | 48 | 16 | 25 | 29 | 29 | |
CGA101*^ | M20 X 1.5 | 1/2" | 6 | 12 | 3 | 8.5 | 47 | 16 | 24 | 26 | 26 | |
CGA1*^ | M20 X 1.5 | 1/2" | 8.5 | 16 | 6 | 12 | 47 | 16 | 25 | 29 | 29 | |
CGA12*^ | M20 X 1.5 | 1/2" | 12 | 20 | 8.5 | 14.5 | 50 | 16 | 28 | 30 | 32 | |
CGA21*^ | M25 X 1.5 | 3/4" | 8.5 | 16 | 6 | 12 | 48 | 18 | 29 | 29 | 29 | |
CGA22*^ | M25 X 1.5 | 3/4" | 12 | 21 | 8.5 | 16 | 53 | 18 | 32 | 34 | 32 | |
CGA2*^ | M25 X 1.5 | 3/4" | 16 | 26 | 12 | 20 | 60 | 18 | 36 | 40 | 40 | |
CGA32*^ | M32 X 1.5 | 1" | 16 | 26 | 12 | 20 | 62 | 18 | 40 | 40 | 40 | |
CGA3*^ | M32 X 1.5 | 1" | 20 | 33 | 15 | 26 | 78 | 18 | 48 | 52 | 52 | |
CGA43*^ | M40 X 1.5 | 1" 1/4 | 20 | 33 | 15 | 26 | 78 | 18 | 48 | 52 | 52 | |
CGA4*^ | M40 X 1.5 | 1" 1/4 | 29 | 41 | 20 | 32 | 89 | 18 | 55 | 60 | 60 | |
CGA54*^ | M50 X 1.5 | 1" 1/2 | 33 | 48 | 22 | 35 | 97 | 18 | 60 | 70 | 74 | |
CGA5*^ | M50 X 1.5 | 1" 1/2 | 36 | 52 | 27 | 41 | 100 | 18 | 70 | 70 | 74 | |
CGA6*^ | M63 X 1.5 | 2" | 43 | 57 | 35 | 45 | 106 | 20 | 75 | 80 | 80 | |
CGA67*^ | M63 X 1.5 | 2" | 47 | 60 | 40 | 52 | 125 | 20 | 90 | 95 | 100 | |
CGA7*^ | M75 X 1.5 | 2" 1/2 | 54 | 70 | 45 | 60 | 125 | 20 | 90 | 95 | 100 | |
CGA8*^ | M90 X 1.5 | 3" | 63 | 80 | 60 | 72 | 154 | 20 | 110 | 115 | 115 |
The cable glands for armoured cables are especially designed to equip with a sole gasket covering a wide range of cable sizes to facilitate the choice and the installation.
The cable glands for non-armoured cables provide with a complete set of internal gaskets to meet any form of requirements.
The upper body of CGF series is female threaded to allow the connection with an Ex d rigid or flexible conduit protecting the cable for specific kind of installations.
The upper body of CGI, CGL and GGV series are designed to hold a flexible watertight flexible conduit protecting the cable for specific kind of installation and with different angles of connection.
The cable glands with cylindrical threads are equipped with O-ring to grant an IP 66/68 protection to the enclosure.
The materials used to manufacture the cable glands have been studied to grant the maximum protection against the highly
corrosive agents present in these industries.
They are available in:
- brass;
- nickel-plated brass;
- stainless steel AISI 316;
The O-ring and internal gaskets are made of neoprene (-40°c / +100°C) and for low and high temperature environments, of silicone
(-60°C / +180°C).
All the equipment have the double marking for Ex d and Ex e installations.
The cable glands to be used with circuit Ex i can be requested with pressure cap painted light blue.
certificate number: IMQ 12 ATEX 010 X TC RU C-IT.AA87.B.00509
marking: II 2GD Ex d IIC Gb - Ex e IIC Gb - Ex tb IIIC Db
ambient temperature: -60°C +180°C (polyuretane gasket) -40°C +100°C (silicone gasket)
degree of protection: IP66 / IP68
conformity: Directive ATEX 2014/34/EU TP TC 012/2011
standards: IEC-EN60079-0 IEC-EN60079-1 IEC-EN60079-7
ГОСТ 31610.0 ГОСТ IEC 60079-1 ГОСТ Р МЭК 60079-7
IEC-EN60079-11 IEC-EN60079-31
ГОСТ 31610.11 ГОСТ Р МЭК 60079-31
category: suitable for Zone 1 - 21 (gas) and Zone 2 - 22 (dust)